Home / CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA)
  • CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA) - Poueer
  • CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA) - Poueer
  • CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA) - Poueer
  • CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA) - Poueer
  • CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA) - Poueer

CGOLDENWALL RW-GT01A DIN Rail mountable load cell sensor amplifier transmitter transducer (Signal Output: 4-20mA)

  • Load cell amplifier RW-GT01A can connect with all kinds of fullbridg strain load cells to measure weight, force, tension etc.. It can adjust, filter and amplify mv electrical signal and output 0-5V(10V) and 4-20mA standard industrial control signal to support PLC or other measuring control system acquisition. <b>Internal active low pass filter can filter out electromagnetic interference </b>in industry site effectively. It takes din rail enclosure to mount easily.
  • 1、Industrial standard guide-way installation and pluggable connection terminal
  • 2、Internal precision amplifying circuit and high accuracy
  • 3、Current and voltage output at the same and arbitrary choice through terminal
  • 4、Connect to all kinds of strain gauge bridge-type load cell, such as weighing, tension, compression, torque and so on
Quantity
ADD TO CART
BUY IT NOW
  • Detail

    Brief Introduction:
    Load cell amplifier RW-GT01A can connect with all kinds of fullbridg strain load cells to measure weight, force, tension etc.. It can adjust, filter and amplify mv electrical signal and output 0-5V(10V) and 4-20mA standard industrial control signal to support PLC or other measuring control system acquisition.
    Internal active low pass filter can filter out electromagnetic interference in industry site effectively. It takes din rail enclosure to mount easily.

    Technical Data:
    Power Supply: 24Vdc(18-27Vdc)
    Max Power:4W (supporting power supply for 350Ωload cell 4 pcs with current output 20mA)
    Wiring Mode: screw-type wiring terminal
    Net Weight:100g
    Dimension:115x37x58mm(LxWxL)
    Operation Temperature Range: -10ºC to 50ºC
    Storage Temperature Range: -20ºC to 80ºC
    Humidity: 85%RH, non condensation
    Load Cell Sensitivity Range: 2.0mV/V±10%
    Voltage Zero Point Adjustment Range: precision tune 10%F.S. ; coarse tune 40% F.S.
    Voltage Full Scale Adjustment Range: 10%F.S.
    Current Zero Point Adjustment Range: 10%F.S.
    Current Full Scale Adjustment Range:10%F.S.
    Accuracy: better than 0.1%F.S.
    Temperature Drift: better than 100ppm
    Load Cell Excitation Voltage: 5Vdc±5%(normal Excitation voltage 5-12V load cell)
    Load Cell Excitation Current: Signal Output: 0-5V or 0-10V and 4-20mA
    Voltage Output Resistance:>5kΩ
    Current Output Resistance: Installation mode: standard din rail mounting